You Position: Home > Paper

Establishing and verifying the threshold value of HLA mixed antigen reagent screening test results

( views:2, downloads:0 )
Author:
No author available
Journal Title:
National Medical Journal of China
Issue:
11
DOI:
10.3760/cma.j.cn112137-20231129-01230
Key Word:
人类白细胞抗原;抗体;界限值;移植;Human leukocyte antigen;Antibodies;Threshold value;Transplantation

Abstract: Objective:To establish the threshold value of human leukocyte antigen (HLA) mixed antigen reagent screening test results, and to verify it by HLA single antigen reagent confirmation test results.Methods:The results of 2 255 serum samples tested for HLA antibodies by HLA mixed antigen reagent in the department of HLA Laboratory, the First Affiliated Hospital of Soochow University from October 2017 to December 2021 were retrospectively analyzed. Among them, 1 139 samples were also tested by single antigen HLA Class-Ⅰ reagent and 1 116 samples were also tested by single antigen HLA Class-Ⅱ reagent. Based on the same antigens coated with both reagents, the Mean Fluorescence Intensity (MFI) and Nomalized Background ratio (NBG ratio) of 12 HLA Class-Ⅰ beads and 5 HLA Class-Ⅱ beads in the HLA mixed antigen reagent and the MFI of 77 anti-HLA class-Ⅰ antibodies and 35 anti-HLA class-Ⅱ antibodies detected by HLA single antigen reagent were recorded. The MFI and NBG ratio of HLA mixed antigen reagent beads in 1 139 or 1 116 samples were segmented according to the positive rate of antibodyies detected by the single antigen reagent corresponding to the antigens coated with each HLA mixed antigen reagent bead, and the results of the HLA mixed antigen screening test were verified by the HLA single antigen reagent confirmation test.Results:The threshold values of MFI and NBG ratio of HLA mixed antigen reagent′s 17 beads were established. The MFI of No. 1 to No. 17 beads of HLA mixed antigen reagent ranged from 26.86 to 21 925.58, and the NBG ratio ranged from 0 to 434.65. According to the positive detection rate of HLA single antigen reagent corresponding to the coated antigens, the MFI and NBG ratio of the beads of HLA mixed antigen reagent were divided into positive interval, suspicious positive interval, suspicious negative interval and negative interval. The positive rates of anti-HLA class-Ⅰ antibodies by HLA mixed antigen reagent and single antigen HLA Class-Ⅰ reagent were 87.5% (997/1 139) and 66.3% (755/1 139). The positive rates of anti-HLA class-Ⅱ antibodies were 63.4% (707/1 116) and 44.9% (501/1 116). In the samples with suspicious negative, suspicious positive and positive results of HLA class-Ⅰ、Ⅱ antibodies detected by HLA mixed antigen reagent, the positive detection rates of single antigen HLA Class-Ⅰ reagent were 14.9% (17/114), 41.3% (145/351) and 91.3% (590/646), respectively. The positive detection rates of single antigen HLA Class-Ⅱ reagent were 15.5% (58/375), 26.5% (81/306) and 88.8% (356/401), respectively.Conclusions:In this study, the threshold values of MFI and NBG ratio of HLA mixed antigen reagent screening test are established, and the threshold values are verified by the results of HLA single antigen reagent confirmation test. HLA mixed reagent screening test can be used for screening of HLA antibodies, and if necessary, it should be combined with HLA single antigen confirmatory test for clinical detection of HLA antibodies.

  • This article has no references!
WanfangData CO.,Ltd All Rights Reserved
About WanfangData | Contact US
Healthcare Department, Fuxing Road NO.15, Haidian District Beijing, 100038 P.R.China
Tel:+86-010-58882616 Fax:+86-010-58882615 Email:yiyao@wanfangdata.com.cn