You Position: Home > Paper

Comparative study on the degree of strabismus and myopia diopter of the pilot candidates with different eye positions

( views:25, downloads:1 )
Author:
No author available
Journal Title:
Chinese Journal of Aerospace Medicine
Issue:
3
DOI:
10.3760/cma.j.cn113854-20210118-00002
Key Word:
外斜视;屈光不正;近视;体格检查;招飞学生;Exotropia;Refractive error;Myopia;Physical examination;Cadet candidates

Abstract: Objective:To investigate the differences of close and distance strabismus degree and spherical equivalence of the students with intermittent exotropia (IXT), exophoria and orthophoria in physical examination of civil aviation recruitment.Methods:The ophthalmic examination data of 13 551 students, who failed in ophthalmology examination of civil aviation recruitment in Chengdu Civil Aviation Medical Center during 2016 to 2020, were collected and analyzed. The yearly trends of their visual, diopter and strabismus failure rates were analyzed. From 2019 to 2020, 69 cases of IXT without vertical strabismus (IXT group), 155 cases of exophoria (exophoria group) and 114 cases of orthophoria (orthophoria group) were found in ophthalmic examination. IXT group was further divided into well-controlled group (55 cases) and badly-controlled group (14 cases) by the eye position controlling ability. Exophoria group was further divided into close strabismus ≤-6 Δ group (98 cases) and >-6 Δ group (57 cases). The myopia rate, spherical equivalent, distance strabismus degree were compared respectively between the well-controlled group and badly-controlled group, close strabismus ≤-6 Δ group and >-6 Δ group, and well-controlled group and close strabismus >-6 Δ group. Results:From 2016 to 2020, the failure rates of diopter and strabismus among the unqualified students in ophthalmology examination of civil aviation recruitment showed an increasing trend. There were significant differences on the degrees of myopia and distance strabismus among different eye position groups ( χ2/ F=93.23, 44.94, 94.04, 365.63, all P<0.001). The spherical equivalence and distance strabismus degree in exophoria group were higher than those in IXT group (both P<0.05). The myopia rate and distance strabismus degree in orthophoria group were lower than those in IXT and exophoria groups (all P<0.05), and the spherical equivalence was higher than that in IXT and exophoria groups (both P<0.05). There were significant differences in diopter detection rates (all P<0.05). Compared with the badly-controlled group, the spherical equivalence of the well-controlled group was lower and the distance strabismus degree was higher, and the differences were statistically significant ( t=2.24, 2.89, both P<0.05). Compared with the close strabismus >-6 Δ group, the close strabismus ≤-6 Δ group had higher distance strabismus degree, and the difference was statistically significant ( t=3.72, P<0.001). There was no significant difference in myopia rate and spherical equivalence between the 2 groups. The spherical equivalence and the distance strabismus degree of the well-controlled group were lower than those of the close strabismus >-6 Δ group, and the differences were statistically significant ( t=3.23, 14.90, P=0.001, <0.001), while there was no significant difference in myopia rate between the 2 groups. Conclusions:The myopia rate and the degree of myopia and distance strabismus in IXT group are the highest, followed by esotropia and orthotropic group.

  • This article has no references!
WanfangData CO.,Ltd All Rights Reserved
About WanfangData | Contact US
Healthcare Department, Fuxing Road NO.15, Haidian District Beijing, 100038 P.R.China
Tel:+86-010-58882616 Fax:+86-010-58882615 Email:yiyao@wanfangdata.com.cn