You Position: Home > Paper

Membrane sampling for the determination of chlorothalonil in the air of workplaces-solvent analysis-Gas Chromatography

( views:39, downloads:16 )
Author:
No author available
Journal Title:
Chinese Journal of Industrial Hygiene and Occupational Diseases
Issue:
4
DOI:
10.3760/cma.j.cn121094-20200313-00126
Key Word:
工作场所;百菌清;溶剂;毛细管;色谱,气相;Workplace;Chlorothalonil;Solvents;Capillary tubing;Gas, Chromatography

Abstract: Objective:To establish a method for the determination of chlorothalonil in air by filtration membrane sampling, solvent elution and gas chromatography.Methods:PTFE filter was used for sampling, eluted with dichloromethane, separated by DB-5 capillary column, and determined by FID.Results:The standard curve was used for quantitative detection, and the correlation of chlorothalonil in the range of 15 μg/ml-300 μg/ml, R2=0.9999. The detection limit of this method was 1.70 μg/ml and the lower quantitative limit was 5.70 μg/ml. The minimum detected concentration was 0.045 mg/m 3 (75L air sample was collected) . The recovery rate was 90.14%-91.81%. The precision of the same batch was 1.5%-1.8%, and that of different batches was 2.3%-3.8%. The sampling efficiency can reach above 95%; The samples can be stored for 14 days at room temperature. Conclusion:The results show that the method of filtration membrane sampling-solvent elude-gas chromatography is suitable for the determination of chlorothalonil in the air.

WanfangData CO.,Ltd All Rights Reserved
About WanfangData | Contact US
Healthcare Department, Fuxing Road NO.15, Haidian District Beijing, 100038 P.R.China