You Position: Home > Paper

Detecting the isoflurane in the air of workplaces with chromatographic method

( views:294, downloads:0 )
Author:
No author available
Journal Title:
Chinese Journal of Industrial Hygiene and Occupational Diseases
Issue:
5
DOI:
10.3760/cma.j.issn.1001-9391.2012.05.023
Key Word:
空气;异氟烷;色谱法,气相;Air;Isoflurane;Gas chromatograph

Abstract: Objective To establish a solvent desorption Gas chromatographic method for detecting the isoflurane in air of workplaces.Methods This method is based on “Standardization of methods for determination of toxic substances in workplace air”.Results This method presents the linear relation with the minimum detectable limit 1.0 μg/ml and the minimum detectable concentration 0.07 mg/m3.The precision (RSD) was 0.5%~5.0%,the mean dsorption efficiencies were 96.7%~98.9%,the absorption efliciencies were 92.1%~100%,the breakthrough volume was 3.7mg isoflurane / 100mg active carbon.Other volatile organic solvents (Sevoflurane,Enflurane and Ethyl Alcohol) did not interfere the detection.The sample could be stored in the active carbon tube at least for 10 days.Conclusion This method is meet the requirement of GBZ/T 210.4-2008“Guide for estabishing occupational health standards-Part4:Determination methods of air chemicals in workplace” and is feasible for determining the isoflurane in the air of workplaces.

WanfangData CO.,Ltd All Rights Reserved
About WanfangData | Contact US
Healthcare Department, Fuxing Road NO.15, Haidian District Beijing, 100038 P.R.China
Tel:+86-010-58882616 Fax:+86-010-58882615 Email:yiyao@wanfangdata.com.cn