You Position: Home > Paper

Clinical observation of three-dimensional printing donor tooth model in peri-operative period of autotransplantation of tooth

( views:0, downloads:0 )
Author:
No author available
Journal Title:
Chinese Journal of Stomatology
Issue:
9
DOI:
10.3760/cma.j.cn112144-20200204-00033
Key Word:
移植,自体;拔牙;外科,口腔;三维打印;Transplantation, autologous;Tooth extraction;Surgery, oral;Three-dimensional printing

Abstract: Objective:To prepare a three-dimensional (3D) printing donor tooth model and to observe its application in the peri-operative period.Methods:In part one, 192 cases (2017.9-2019.8) from Department of Oral & Maxillofacial Surgery, School of Stomatology, The Fourth Military Medical University [107 males and 85 females, age (34.2±10.7) years] which need autotransplantation of teeth (ATT) were collected. Whether the donor teeth can be completely extracted was predicted through clinical and imaging examination (first prediction). The second prediction was supplemented by the three-dimensional printing model of the donor teeth. Each of the prediction was compared with the actual results and the coincidence rate was calculated. In part two, 64 cases (2017.9-2019.8) from Department of Oral & Maxillofacial Surgery, School of Stomatology, The Fourth Military Medical University [28 males, 36 females, age (30.2±8.3) years] which need ATT were randomly divided into the model group and the donor group. The time of alveolar fossa preparation, time of donor tooth in vitro, times of trial implantation and time of pulptomy and root canal location were recorded respectively. Results:In part one, the coincidence rate between the second prediction and the actual results [97.4%(187/192)] was significantly higher than that of the first prediction [93.2%(179/192)] ( P<0.05). In part two, the preparation time of the alveolar fossa in the maxillary and mandibular were (18.8±4.6) and (22.7±3.4) min, the time of the teeth in vitro were (3.0±0.6) and (2.1±0.6) min, the times of trial implantation were (1.3±0.8) and (1.0±0.9), and the time of pulpotomy and root canal location were (4.3±0.6) and (4.0±0.5) min. All values in the model groups were better than those in the donor group ( P<0.05). Conclusions:The 3D printing model is accurate. It can be used in autogenous tooth transplantation to shorten the preparation time of alveolar fossa and time of donor tooth in vitro, and reduce the times of trial implantation of donor teeth, and to help to improve the prediction accuracy of complete extraction of donor teeth and the time of pulpotomy and root canal location.

WanfangData CO.,Ltd All Rights Reserved
About WanfangData | Contact US
Healthcare Department, Fuxing Road NO.15, Haidian District Beijing, 100038 P.R.China
Tel:+86-010-58882616 Fax:+86-010-58882615 Email:yiyao@wanfangdata.com.cn