You Position: Home > Paper

Analysis of risk factors of 19 fractured implants

( views:404, downloads:188 )
Author:
No author available
Journal Title:
Chinese Journal of Stomatology
Issue:
12
DOI:
10.3760/cma.j.issn.1002-0098.2018.12.005
Key Word:
牙种植;牙种植体;种植体折断;种植体-基台连接;Dental implantation;Dental implants;Implant fracture;Implant-abutment interaction

Abstract: Objective To analyze the incidence and possible risk factors of 19 fractured implants out of 8 468 implants in 3 184 cases. Methods During the 22-year clinical practice, clinical records of 18 patients with 19 fractured implants in 3 184 cases with 8 468 implants were analyzed to determine the following factors: location of the fractured implants, prosthodontics option, date of implant fracture, dimensions of fractured implants, complications prior to implant fracture and parafunctional habit. An evaluation of fractured implants was performed to identify possible factors that may predispose an implant to a higher risk of fracture. Results Overall, the average duration of service of the implants was (7.0±4.5) years. Implant fracture occurred in 7 Camlog implants, 7 Nobel replace implants, 3 Ankylos implants and 2 Br?nemark implants. No Thommen implant fractures were recorded. Amongst the 19 fractured implants, 8 occurred at the thinnest wall portion of the implant neck, 8 at the end of screw and 3 at the self-tapping thread region. All fractures were observed after functional loading. Furthermore, 9/19 (47.4%) of fractures occurred in the maxilla, indicating similar incidence rates in both arches (P=0.065). Most of fractures (16/19) occurred in the molar region and 18/19 in single implant-supported restorations. Totally 17 cases had received metal occlusal restorations. In 6 cases (35.5%), previous bone destruction apically extending to the level of implant fracture was documented before any clinical signs of fracture. Three fractured implants were removed and simultaneously re-implanted with larger-diameter implants, while the rest of the cases were left to heal, followed by a second-stage surgery. Conclusions Within the limitation of this analysis, the study demonstrated that appropriate implant-abutment connection design, implant diameter, prosthetic strategy and bone resorption are crucial to the long-term performance of implants. There is no significant difference of fractures rates in both archs.

WanfangData CO.,Ltd All Rights Reserved
About WanfangData | Contact US
Healthcare Department, Fuxing Road NO.15, Haidian District Beijing, 100038 P.R.China
Tel:+86-010-58882616 Fax:+86-010-58882615 Email:yiyao@wanfangdata.com.cn