Consistency study of FRACTURE sequence and CT in evaluating bone changes of knee and ankle

( views:0, downloads:0 )
Author:
No author available
Journal Title:
Chinese Journal of Radiology
Issue:
3
DOI:
10.3760/cma.j.cn112149-20220207-00094
Key Word:
磁共振成像;膝关节;踝关节;基于受限回波间距的快速梯度回波类CT成像;Magnetic resonance imaging;Knee joint;Ankle joint;Fast field echo resembling a CT using restricted echo-spacing

Abstract: Objective:To explore the consistency of MRI fast field echo resembling a CT using restricted echo-spacing (FRACTURE) and CT in the evaluation of knee and ankle bone changes.Methods:From November 2020 to November 2021, seventeen patients who underwent CT and MRI FRACTURE examinations of knee joint or ankle joint in the First Affiliated Hospital of Dalian Medical University were retrospectively collected, including 14 patients with knee joint examinations and 3 patients with ankle joint examinations. According to the number of joint components, 80 components were included, including 14 for femur and patella, 17 for tibia and fibula, and 3 for talus, scaphoid, medial cuneiform, medial cuneiform, lateral cuneiform and calcaneus, respectively. The fracture, hyperosteogeny, and bone destruction of the joint bones were evaluated by two observers using CT and FRACTURE images, respectively. Kappa test was used to analyze the consistency of CT and FRACTURE images between observers in the evaluation of joint bone lesions.Results:The Kappa values (95%CI) of the consistency evaluation of fracture, hyperosteogeny, and bone destruction by CT and FRACTURE images were 0.925 (0.823-1.027), 0.905 (0.799-1.011) and 0.895(0.752-1.038) respectively for observer 1, and were 0.963 (0.892-1.034), 0.933 (0.843-1.023) and 0.886 (0.731-1.041) respectively for observer 2. The Kappa values (95%CI) of the consistency evaluation of fracture, hyperosteogeny, and bone destruction by observers 1 and 2 via CT images were 1.000 (1.000-1.000), 0.937(0.851-1.023) and 0.945 (0.839-1.051) respectively, and that by FRACTURE images were 0.962 (0.888-1.036), 0.966 (0.899-1.033) and 0.836 (0.656-1.016) respectively.Conclusion:For the evaluation of fracture, hyperosteogeny, and bone destruction of knee joint and ankle joint, MRI FRACTURE sequence is highly consistent with CT.

  • This article has no references!
WanfangData CO.,Ltd All Rights Reserved
About WanfangData | Contact US
Healthcare Department, Fuxing Road NO.15, Haidian District Beijing, 100038 P.R.China
Tel:+86-010-58882616 Fax:+86-010-58882615 Email:yiyao@wanfangdata.com.cn