You Position: Home > Paper

Effect of deep learning image reconstruction algorithm on CT image quality and detectability of hypovascular hepatic metastases at low radiation dose levels

( views:79, downloads:1 )
Author:
No author available
Journal Title:
Chinese Journal of Radiology
Issue:
11
DOI:
10.3760/cma.j.cn112149-20220124-00070
Key Word:
肝肿瘤;肿瘤转移;体层摄影术,X线计算机;辐射剂量;深度学习重建算法;图像质量;Liver neoplasams;Neoplasm metastasis;Tomography, X-ray computed;Radiation dosage;Deep learning image reconstruction;Image quality

Abstract: Objective:To investigate the efficiency of deep learning image reconstruction (DLIR) algorithm in the image quality and detection of hypovascular hepatic metastases under low radiation doses in comparison with adaptive statistical iterative construction-V (ASiR-V).Methods:Fifty-six patients with suspected hypovascular hepatic metastases who needed abdominal enhanced CT scans were collected prospectively in the First Affiliated Hospital of Zhengzhou University from January to April 2021. The patients received conventional radiation dose with tube current-time products of 400 mA CT scans in the first venous phase, low-dose CT scans in the second venous phase, which were set as tube current-time products of 280 mA for group A (19 cases), 200 mA for group B (19 cases) and 120 mA for group C (18 case), respectively. The images of first venous phase and 3 groups of second venous phase were both reconstructed with ASiR-V60% and high-DLIR (DLIR-H). Quantitative parameters [image noise, liver and portal vein signal to noise ratio (SNR), contrast to noise ratio (CNR)] and qualitative parameters (overall image quality, lesion conspicuity, diagnostic confidence) were compared between ASiR-V60% and DLIR-H images, and the effective radiation dose (ED) and the lesion detectability of each group was recorded. The paired t test was used to compare quantitative parameters, whereas the Wilcoxon signed-rank test of paired data was used to compare qualitative parameters. Results:In the second venous phase, ED was (5.56±0.35) mSv in group A, (3.88±0.23) mSv in group B, and (2.42±0.23) mSv in group C, with a decrease of 30%, 50% and 70% compared with the first venous phase, respectively. Moreover, with the decrease of radiation dose, the noise gradually increased, and the CNR lesions, SNR liver and SNR portal vein all gradually decreased. DLIR-H images had statistically better quantitative scores than ASiR-V60% images when the same radiation dose was applied (all P<0.001). Furthermore, the qualitative parameters of each group decreased with the decrease of radiation dose. Under the same radiation dose, the overall image quality, lesion conspicuity and diagnostic confidence of DLIR-H were higher than those of ASiR-V60% (all P<0.001). All lesions [100% (84/84)] were detected by ASIR-V60% and DLIR-H in group A, 92.0% (75/81) in group B, and 88.0% (79/89) in group C. Conclusions:Compared with ASiR-V60%, DLIR-H could reduce image noise, improve overall image quality and lesion conspicuity of hypovascular hepatic metastases as well as increase diagnostic confidence under different radiation doses.

WanfangData CO.,Ltd All Rights Reserved
About WanfangData | Contact US
Healthcare Department, Fuxing Road NO.15, Haidian District Beijing, 100038 P.R.China
Tel:+86-010-58882616 Fax:+86-010-58882615 Email:yiyao@wanfangdata.com.cn