You Position: Home > Paper

Efficacy and safety of MR guided focused ultrasound surgery for symptomatic uterine fibroids

( views:294, downloads:224 )
Author:
No author available
Journal Title:
中华放射学杂志
Issue:
2
DOI:
10.3760/cma.j.issn.1005-1201.2017.02.015
Key Word:
子宫肿瘤;平滑肌瘤;高强度聚焦超声消融;治疗结果;Uterine neoplasms;Leiomyoma;High-intensity focusd ultrasound ablation;Treatment outcome

Abstract: Objective To evaluate the safety and clinical efficacy of the treatment for symptomatic uterine fibroids with MR guided focused ultrasound surgery(MRgFUS)in China. Methods Twenty five selected patients with symptomatic uterine fibroids underwent MRgFUS treatment in our perspective clinical study. Immediately after treatment the patients accepted pelvic enhanced MRI scans, and recorded the non-perfused volume(NPV)and calculated the non-perfused volume ratio(NPV%). We recorded the symptom severity score(SSS) and standard SSS change(ΔSSS)of the patients before, during and 1 week after treatment together with 1, 3, 6, 12 months and several years follow-up. The patients accepted pelvic enhanced MRI scans in the follow-up of 12 months after treatment,and recorded the volume and the volume change(ΔV) of fibroids. We observed the adverse reactions during the treatment and the follow-ups. Wilcoxon test or t test and Pearson or Spearman correlation analysis were used to analyze the data. Results Totally 31 fibroids of 25 patients were completed the treatment. Twenty two patients completed the 12 months follow-up and 15 patients completed the long-term follow-up which was during 34 to 66 months,&nbsp;median follow-up duration was(55 ± 11)months. The NPV was 4.5 to 295.0 cm3, median was 37.0 cm3. The NPV%was 6%to 94%, average was(64 ± 23)%. According to our follow up, the standard SSS continued to decline. Compared with screening standard SSS, all the follow-up standard SSS had significant difference(P<0.05), except for that of the first week. Among all the follow up, only the standard SSS change of 1 week after the treatment had a correlation with NPV%(r=0.552,P=0.005), and the others had no significant correlation with NPV%(P>0.05). The uterine fibroids volume decreased in the 12 months follow-up, which had a significant difference with the volume before treatment(P<0.05). And there was also correlation between the fibroids volume change and NPV(r=0.587,P=0.017). There was no correlation between the volume or volume change and standard SSS or standard SSS change(all P>0.05). None serious adverse effects occurred in all cases. Conclusion MRgFUS is a safe and effective way to treat uterine fibroids.

WanfangData CO.,Ltd All Rights Reserved
About WanfangData | Contact US
Healthcare Department, Fuxing Road NO.15, Haidian District Beijing, 100038 P.R.China
Tel:+86-010-58882616 Fax:+86-010-58882615 Email:yiyao@wanfangdata.com.cn