You Position: Home > Paper

Clinical application of gemstone spectral imaging associated with patient-based low dose of contrast medium protocol for carotid CT angiography

( views:477, downloads:489 )
Author:
No author available
Journal Title:
Chinese Journal of Radiology
Issue:
10
DOI:
10.3760/cma.j.issn.1005-1201.2015.10.012
Key Word:
体层摄影术,X线计算机;颈动脉;造影剂;Tomography,X-ray computed;Carotid artery;Contrast medium

Abstract: Objective To investigate the clinical value of gemstone spectral imaging (GSI) associated with patient-based low dose of contrast medium protocol in carotid CTA. Methods One hundred and twenty patients who were suspected with stenotic carotid artery or carotid plaque were prospectively enrolled in the study. All of them were divide into two groups by random number table. Group A (routine group): 60 were scanned with 120 kVp after the administration of moderate-concentration CM(320 mg/ml) with 5 ml/s injection velocity, Group B (low dose group):60 were scanned with GSI which was reconstructed using 50%ASiR after the administration of the same CM with 3 ml/s injection velocity. The contrast dose [(test bolus peak time +2 s – 5 s) × injection velocity] was calculated. Images of the two groups were compared in terms of arterial attenuation, signal-noise-ratio (SNR), contrast-to-noise ratio (CNR), and subjective image quality (IQ) score. The value of CT dose index volume (CTDIvol), dose length product (DLP) and effective dose (ED) was recorded, respectively. Data were analyzed by using independent samples t test or Mann-Whitney U test. Results The mean attenuation, noise, SNR, CNR, subjective image quality score, contrast dose, CTDIvol, DLP and ED of routine group was (363 ± 56)HU, (13 ± 4)HU, 30 ± 10, 38±13, 3.0 score, (69 ± 13) ml, 13.61 mGy,527 mGy · cm and 3.11 mSv, respectively. The above variables of low-dose-group was (378 ± 69) HU, (9 ± 4)HU, 48 ± 19, 62 ± 24, 2.0 score,(49 ± 7)ml, 12.72 mGy, 478 mGy · cm and 2.82 mSv, respectively. The mean attenuation and subjective IQ score of carotid artery had no significant differences statistically between two groups (P>0.05), respectively. The noise, SNR, CNR, contrast dose, CTDIvol, DLP and ED had significant differences statistically between two groups (P<0.05), respectively. Conclusion Compared with 120 kVp protocol, the use of GSI associated with patient-based low dose of contrast medium protocol in carotid CTA could provide equivalent image quality and higher SNR and CNR of carotid artery with a smaller amount of iodine and a lower radiation dose.

WanfangData CO.,Ltd All Rights Reserved
About WanfangData | Contact US
Healthcare Department, Fuxing Road NO.15, Haidian District Beijing, 100038 P.R.China
Tel:+86-010-58882616 Fax:+86-010-58882615 Email:yiyao@wanfangdata.com.cn