You Position: Home > Paper

Radiation dose reduction of coronary CT angiography at low tube voltage on an integrated circuit detector with iterative reconstruction

( views:785, downloads:296 )
Author:
No author available
Journal Title:
Chinese Journal of Radiology
Issue:
2
DOI:
10.3760/cma.j.issn.1005-1201.2014.02.006
Key Word:
冠状血管;体层摄影术,X线计算机;血管造影术;辐射剂量;Coronary vessel;Tomography,X-ray computed;Angiography;Radiation dosage

Abstract: Objective To investigate the value of low tube voltage (80 kV) for coronary computed tomography angiography (CCTA) in patients with normal body mass index (BMI) on 128-slice dual-source CT with novel high sensitive integrated circuit (IC) detector.Methods One hundred and three consecutive patients were scanned using prospectively ECG-triggered sequential CCTA protocol.All patients were randomly divided into group A and B.Group A was examined on a conventional 128-slice dual-source CT,while group B on a 128-slice dual-source CT with high sensitive integrated circuit detector.The tube voltage of group A was 100 kV and raw data was reconstructed with filtered back projection (FBP),while tube voltage of group B was 80 kV and raw data was reconstructed with both FBP (Subgroup B1) and sonogramaffirmed iterative reconstruction (SAFIRE) (Subgroup B2).The differences in background noise,signal-tonoise ratio (SNR),contrast-to-noise ratio (CNR),CT dose index volume (CTDIvol),effective dose (ED),and image quality between the groups were compared by using t test,ANOVA and x2 test.Results There were no significant differences in age,BMI or heart rate between the two groups (Group A,n =52 vs.Group B,n =51).Radiation exposure (CTDIvol and ED) of group B was significantly lower than that of group A [(8.93 ±2.55) vs.(13.87 ±4.62) mGy and (1.77 ±0.51)vs.(2.65 ±0.89) mSv,t =6.71,6.09,all P < 0.01].SNR and CNR of proximal coronary arteries in group B2 were significantly higher than group A and B1,and there was no significant difference between the latter two.In group A,mean score of total 839 coronary artery segments was 1.29 ± 0.23,and the number of evaluable segments was 813 (96.9%).In group B1,mean score of total 820 coronary artery segments was 1.34 ± 0.29,and the number of evaluable segments was 789 (96.2%).In group B2,mean score of total 820 coronary artery segments was 1.33 ± 0.31,and the number of was 791 (96.5%).There were no significant differences in both mean score and percentage of evaluable segments between three groups (x2 =1.81,P > 0.05).Conclusion Using 80 kV tube voltage on 128-slice dual-source CT equipped with novel integrated circuit detector and combining iterative reconstruction is feasible in patients with normal BMI,with the benefits of significantly reduced radiation dose and adequate image quality.

WanfangData CO.,Ltd All Rights Reserved
About WanfangData | Contact US
Healthcare Department, Fuxing Road NO.15, Haidian District Beijing, 100038 P.R.China
Tel:+86-010-58882616 Fax:+86-010-58882615 Email:yiyao@wanfangdata.com.cn