You Position: Home > Paper

Detection of macular foveal by optical coherence tomography and its influence on results of measurement of central retina thickness

( views:415, downloads:76 )
Author:
No author available
Journal Title:
Chinese Journal of Ophthalmology
Issue:
10
DOI:
10.3760/cma.j.issn.0412-4081.2012.10.006
Key Word:
体层摄影术,光学相干;视网膜;中央凹;人体测量术;Tomography,optical coherent;Retinal;Fovea centralis;Anthropometry

Abstract: Objective To detect macular foveal by CirrusTM HD-OCT using the post acquisition fovea detection and to study its influence on the results of measurement of central retina thickness (CRT).Methods In this retrospectively studies,the 512 × 128 cube scans from 50 eyes of normal subjects and 50 eyes of macular edema patients were analyzed.Three methods for the foveal detection were used,the scan center (SC),the automated detected foveal (AF) and the manually identified foveal (MF).The foveal detected by MF was set as the reference.Radial distances from SC and AF to MF were calculated.Subfields retinal thickness acquired from different groups using different foveal detection methods were compared by paired Student's t test for normal data or Wilcoxon-Mann-Whitney for non-normal data.Results For normal subjects,it is reliable determing the foveal by special tomography features.The means of the radial distance from the MF was (35.0 ± 23.O) μm in scan center group and was (6.0 ± 9.0) μm in automated center (t=-3.732,P <0.05).The average CRT difference between the SC and MF groups was (7.4 ±10.4) μm.The median difference between the AF and MF groups was 0 μm (0 to 3),which is significantly less than that between the SC and MF groups (Z =-2.956,P < 0.05).In subjects with macular edema,the means of the radial offset was (59.0 ± 26.0) μm in SC group and was (34.0 ± 23.0)μm in AF group (t =-4.555,P < 0.05).The average CRT difference between the SC and MF groups was (28.0 ± 36.0) μm,which was not significantly greater than the difference between the AF and MF groups (23.0 ± 31.0) μm in macular edema eyes.Conclusions Post acquisition detection of foveal reduces the radial offset to the real fovea,and may improve the reproducibility and reliability of the central retinal thickness qtantification using spectral domain OCT in normal subjects.

WanfangData CO.,Ltd All Rights Reserved
About WanfangData | Contact US
Healthcare Department, Fuxing Road NO.15, Haidian District Beijing, 100038 P.R.China
Tel:+86-010-58882616 Fax:+86-010-58882615 Email:yiyao@wanfangdata.com.cn