You Position: Home > Paper

Comparison of three approaches to delineate internal gross tumor volume based on four-dimensional CT simulation images of non-small-cell lung cancer

( views:479, downloads:140 )
Author:
No author available
Journal Title:
CHINESE JOURNAL OF RADIATION ONCOLOGY
Issue:
2
DOI:
10.3760/cma.j.issn.1004-4221.2011.02.006
Key Word:
癌,非小细胞肺/放射疗法;体层摄影术,X线计算机,四维;内大体肿瘤靶体积;呼吸时相;Carcinoma,non-small-cell lung/radiotherapy;Tomography,X-ray computed,fourdimensional;Internal gross tumor volume;Respiratory phase

Abstract: Objective To compare positional and volumetric differences of internal gross tumor volume (IGTV) delineated separately by three approaches based on four-dimensional CT (4DCT) for the primary tumor of non-small cell lung cancer (NLCLC). Methods Twenty-one patients with NLCLC underwent big bore 4DCT simulation scan of the thorax. IGTVs of the primary tumor of NSCLC were tumor on the MIP images were delineated to produce IGTVMIP. The position of the target center, the volume of target, the degree of inclusion (DI) and the matching index (MI) were compared reciprocally between IGTV10, IGTVEI+EE and IGTVMIP. Results Average differences between the position of the center of IGTVs on direction of x,y and z axes were less than 1 mm, with no statistically significant difference. The volume of IGTV10 was larger than that of IGTVEI+EE, the difference was statistically significant (t=2.37,P=0.028);the volume of IGTV10 was larger than that of IGTVMIP, but the difference was not statistically significant(t=1.95 ,P=0.065). The ratio of IGTVEI+EE with IGTV10, IGTVMIP with IGTV10 were 0.85±0.08 and 0.92±0.11, respectively. DI of IGTVEI+EE in IGTV10, IGTVMIP in IGTV10 were 84.78% ± 8. 95% and 88.47% ±9.04%. MI between IGTV10 and IGTVEI+EE, IGTV10 and IGTVMIP were 0.85 ±0.09, 0.86±0. 09, respectively. Conclusions The center displacement of the IGTVs delineated separately by the three different techniques based on 4DCT images are not obvious; IGTVEI+EE and IGTVMIP can not replace IGTV10 , however , IGTVMIP is more close to IGTV10 comparing to IGTVEI+EE . The ratio of GTVEI+EE with IGTV10 is correlated to the tumor motion vector. As the vector increases, the ratio of GTVEI+EE with IGTV10decreases, especially for small tumors.

WanfangData CO.,Ltd All Rights Reserved
About WanfangData | Contact US
Healthcare Department, Fuxing Road NO.15, Haidian District Beijing, 100038 P.R.China
Tel:+86-010-58882616 Fax:+86-010-58882615 Email:yiyao@wanfangdata.com.cn