You Position: Home > Paper

Anatomy of palatovaginal canal in normal adults: multi-slice spiral CT and curved planar reconstruction studies

( views:370, downloads:124 )
Author:
No author available
Journal Title:
CHINESE JOURNAL OF RADIOLOGY
Issue:
4
DOI:
10.3760/cma.j.issn.1005-1201.2009.04.003
Key Word:
腭鞘管;腭,硬;蝶骨;体层摄影术;X线计算机;放射摄影术;全景;Palatovaginal canal;Palate,hard;Sphenoid bone;Tomography,X-raycomputed;Radiography,panoramic

Abstract: Objective To muhi-directionally visualize and measure the normal anatomy of palatovaginal canal and its communications with high-resolution multi-slice spiral CT and its post-processing technologies.Methods One hundred and sixty-seven subjects with normal PPF and its communications were examined by 16-MSCT using high-resolution technique.The MPR and CPR images of palatovaginal canal were obtained on postproeessing workstation.The length and diameter of the palatovaginal canal and its communications was measured and analyzed with one way ANOVA analysis and independent samples t test.Results In this study, the detection rate of palatovaginal canal on 167 subjects was 98.8% (330/334).The mean length of left and right palatovaginal canal was (1.18 ± 0.22) cm and (1.07 ± 0.29) cm, respectively.The mean diameter of anterior opening (0.19±0.06)cm was significantly larger than median (0.10 ± 0.04) cm and posterior opening (0.16 ± 0.07)cm in left palatovaginal canal (F = 211.109, P < 0.01).Similarly,The mean diameters of anterior, median and posterior opening in right palatovaginal canal were (0.19±0.06)cm, (0.10±0.03)cm and(0.16±0.06) cm, respectively (F = 139.350,P <0.01).No significant difference on length measurements was revealed between the men [left: (1.18±0.22) cm; right: (1.12 ± 0.31)cm] and women [left: (1.07±0.25)cm; fight: (1.02±0.25)cm] (left: t = 0.919, P > 0.05 ;right:t = 1.117,P > 0.05).Between the men [left: (0.19±0.06) cm, (0.10 +0.04) cm and (0.16±0.07) cm; right: (0.19±0.06) cm,(0.10±0.04) cm,(0.16±0.06) cm] and women [left: (0.20±0.08) cm, (0.10±0.04) cm and (0.15±0.05) cm; right: (0.20±0.06) cm, (0.09± 0.04) cm and (0.15±0.05) cm], no significant difference on diameter measurements was revealed (left: t =- 1.183,0.190 and 1.660 ; fight: t = - 1.420,1.210 and 0.802 ; all P > 0.05).Conclusion On the basis of high-resolution MDCT scan, MPR and CPR images could visualize clearly the morphologic features of the palatovaginal canal, which may be helpful for making diagnostic and therapeutic decisions because more imaging information could be obtained.

WanfangData CO.,Ltd All Rights Reserved
About WanfangData | Contact US
Healthcare Department, Fuxing Road NO.15, Haidian District Beijing, 100038 P.R.China
Tel:+86-010-58882616 Fax:+86-010-58882615 Email:yiyao@wanfangdata.com.cn